Showing results: 16 - 30 of 537 items found.
-
778965-01 -
NI
64-Channel, ±30 VDC, 32 Sink/Source Inputs, 32 Source Outputs, Bank-Isolated PXI Digital I/O Module—The PXI‑6514 is an industrial digital I/O interface with eight banks of isolated channels. With programmable power-up states, you can configure the initial output states in software to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PXI‑6514 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.
-
778967-01 -
NI
64-Channel, ±30 VDC, Sink/Source Inputs, Bank-Isolated PXI Digital I/O Module—The PXI‑6511 is an industrial digital input interface, with eight banks of isolated channels. If a computer or application fault occurs, the PXI‑6511 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.
-
779083-01 -
NI
The PCI-6517 is an industrial digital output interface, with one bank of channels. The device is ideal for industrial control and manufacturing test applications. The PCI-6517 module is an industrial digital I/O interface, with eight banks of isolated channels. You can wire each input bank in a source or sink configuration. With programmable power-up states, you can configure the initial output states in software, to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PCI-6517 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions.
-
779082-01 -
NI
The PCI-6516 is an industrial digital output interface, with one bank of channels. The device is ideal for industrial control and manufacturing test applications. The PCI-6516 module is an industrial digital I/O interface, with all channels on an isolated bank. You can wire each input bank in a source or sink configuration. With programmable power-up states, you can configure the initial output states in software, to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PCI-6516 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions.
-
778964-01 -
NI
64-Channel, ±30 VDC, 32 Sink/Source Inputs, 32 Sink Outputs, Bank-Isolated PXI Digital I/O Module—The PXI‑6515 is an industrial digital I/O interface with eight banks of isolated channels. You can wire each input bank in a source or sink configuration. With programmable power-up states, you can configure the initial output states in software to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PXI‑6515 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.
-
779949-01 -
NI
48-Channel, Sink/Source Inputs, Channel-Channel Isolated PXI Digital I/O Module—The PXI‑6529 is an industrial, parallel digital input interface. PXI‑6529 devices are ideal for a variety of applications from automotive design, industrial factory automation, and machine control to aerospace, laboratory research, and biomedical applications. With programmable power-up states, you can configure the initial output states in software to ensure safe operation when connected to industrial actuators. If a computer or application fault occurs, the PXI‑6529 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.
-
41-765-001 -
Pickering Interfaces Ltd.
The 41/43-765-001 is a PXI/PXIe 16-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
41-765-002 -
Pickering Interfaces Ltd.
The 41/43-765-002 is a 12-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
41-765-003 -
Pickering Interfaces Ltd.
The 41/43-765-003 is an 8-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
41-765-004 -
Pickering Interfaces Ltd.
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
GX1642 -
Marvin Test Solutions, Inc.
The GX1642 is a 3U PXI digital to analog output board is designed specifically for applications where multiple analog outputs are required. The GX1642 offers precision signal sourcing performance and quality at an economical price.
-
GX1648 -
Marvin Test Solutions, Inc.
The GX1648 is a 3U PXI digital to analog output board is designed specifically for applications where multiple analog outputs are required. The GX1648 offers precision signal sourcing performance and quality at an economical price.
-
cPCI-6208/6216 Series -
ADLINK Technology Inc.
- PICMG 2.0 Rev 2.1- 16-bit D/A resolution- 16-CH voltage on 6216V- 8-CH voltage outputs on 6208A and 6208V- 8-CH current outputs on 6208A- Bipolar analog output range- 4-CH TTL DI and 4-CH TTL DO- Rear I/O available
-
PCI-7256 -
ADLINK Technology Inc.
*Supports a 32-bit 3.3 V or 5 V PCI bus*16-CH latching SPDT relay outputs*Power saving on relay actuation*Output status unchanged when power-off*On-board LED indicators for relay status
-
PCIe-7256 -
ADLINK Technology Inc.
ADLINK's PCIe-7256 features all Form C type relays, ideal for device connection with on/off control. With latching relays, the PCIe-7256 further provides operating power conservation, while the status of each latching relay output is indicated by onboard LED. When the relay is in SET, its corresponding LED lights. Latching relays also feature unchanged status even when the system powered off, making the PCIe-7256 suitable for critical applications requiring output status to be maintained even under fault conditions. All digital input channels are non-polar and optically isolated, and may be set for optional use of RC filter. The PCIe-7256 also features a change-of-state (COS) function generating interrupt when any digital input changes state.